Brocade Network Advisor SAN + IP User Manual v12.1.0 User Manual

Page 1177

Advertising
background image

1124

Brocade Network Advisor SAN + IP User Manual

53-1002949-01

Adding an FCIP circuit

27

3. Select the IP Address Type. The implementation is a dual IP layer operation implementation as

described in RFC 4213. IPv6 addresses can exist with IPv4 addresses on the same interface,
but the FCIP circuits must be configured as IPv6 to IPv6 and IPv4 to IPv4 connections.
IPv6-to-IPv4 connections are not supported. Likewise, encapsulation of IPv4 in IPv6 and IPv6
in IPv4 is not supported.

4. Select the IP Address for each port. This implementation of IPv6 uses unicast addresses for

the interfaces with FCIP circuits. The unicast address must follow the RFC 4291 IPv6 standard
and use the IANA assigned IPv6 Global Unicast address space (2000::/3).

5. For IPv4 addresses, specify the Subnet Mask. For IPv6 addresses, specify the prefix length.

The default is created from the IP address and Subnet Mask. If you want to create a route
through a gateway router, click Create Non-Default Route, and select a Gateway address.

6. Enter the MTU Size.

For SAN traffic, the largest possible MTU (Maximum Transmission Unit) size is generally the
most efficient. Enter a value between 1260 and 2348 for the 4 Gbps platforms and between
1260 and 1500 for the 8 Gbps platforms. MTU rates must match on both ends of the tunnel.

If you have an active connection between switch one and switch two, click Verfiy IP
Connectivity under Switch One Settings to test the connection. To determine a suggested size,
packets are sent across the FCIP tunnel, starting at the largest possible size packet that can
be sent over IP. If a valid connection response is not received, a smaller packet is sent. This
continues until a valid connection response is received, and that size becomes the suggested
MTU. MTU settings must match at both ends of the tunnel, and the setting specified under
Switch One Settings is automatically applied to switch two.

NOTE

Verify IP Connectivity button function requires an active IP connection. The button is not
available for the Add FCIP Circuit and Edit FCIP Circuit dialog boxes for 8 Gbps Extension
platforms.

7. If a VLAN ID is used to route frames between the switches over the physical connection, enter

the VLAN ID under Switch One Settings. You must assign the VLAN ID to both switches. You can
assign the same or different VLAN IDs to each switch.

The VLAN ID is an integer value between 1 and 4094 which sets the VLAN tag value in the
header assigning the traffic to that specific VLAN. Layer two class of service (L2CoS) values
may be assigned to establish traffic priorities over a VLAN. This is done as an Advanced
Setting.

8. The Metric option is used to identify a failover circuit. By assigning a non-zero metric (1), you

identify the circuit as a failover circuit. By default, a circuit is assigned a metric of 0. If a metric
0 circuit fails, FCIP trunking tries first to retransmit any pending send traffic over another circuit
with a metric of 0. If no circuits with a metric of 0 are available, then the pending send traffic is
retransmitted over any available circuit with a metric of 1.

The default metric value for a crossport circuit configuration will be 1. If a failover circuit is
created with a metric of 0, it will be used for load balancing and not for failover.

Advertising