MAPS monitoring categories

50

FRU monitoring category

The FRU category enables you to define rules for field replaceable units (FRU), including ports,
power supplies, and flash memory.

Table 177

lists measures in the FRU category and describes each measure. Possible states for all

FRU measures are faulty, inserted, on, off, ready, and up.

Security monitoring category

The Security category monitors different security violations on the switch and takes action based
on the configured thresholds and their actions.

Table 178

lists measures in the Security category and describes what each measure indicates.

TABLE 177

FRU measures

Measure

Description

Power Supplies (PS_STATE)

State of a power supply has changed.

Fans (FAN_STATE)

State of a fan has changed.

Blades (BLADE_STATE)

State of a blade has changed.

SFPs (SFP_STATE)

State of the SFP has changed.

WWN

State of a world wide name (WWN) card has changed.

TABLE 178

Security measures

Measure

Description

DCC violations (SEC_DCC)

An unauthorized device attempts to log in to a secure fabric.

HTTP violations (SEC_HTTP)

A browser access request reaches a secure switch from an unauthorized IP
address.

Illegal command (SEC_CMD)

Commands permitted only to the primary fabric configuration server (FCS)
are executed on another switch.

Incompatible security DB (SEC_IDB) Secure switches with different version stamps have been detected.

Login violations (SEC_LV)

Login violations that occur when a secure fabric detects a login failure.

Invalid certifications (SEC_CERT)

There is a missing or invalid certificate file.

No-FCS (SEC_FCS)

The switch has lost contact with the primary FCS.

SCC violations (SEC_SCC)

SCC violations that occur when an unauthorized switch tries to join a secure
fabric. The WWN of the unauthorized switch appears in the ERRLOG.

Security authentication failures
(SEC_AUTH_FAIL)

Authentication failures that occur when packets try to pass from a
nonsecure switch to a secure fabric.

Telnet violations (SEC_TELNET)

Telnet violations that occur when a Telnet connection request reaches a
secure switch from an unauthorized IP address.

TS out of sync (SEC_TS)

Time Server (TS) violations that occur when an out-of-synchronization error
has been detected.