Brocade Network Advisor SAN + IP User Manual v12.1.0 User Manual

Page 1537

Advertising
background image

1490

Brocade Network Advisor SAN + IP User Manual

53-1002949-01

Bottleneck detection

43

When changing switch-level parameters, such as time and severity threshold values,
bottleneck detection will be disabled, then enabled.

If ineligible ports later become eligible or, in the case of a logical switch, if ports are moved to the
logical switch, bottleneck detection is automatically applied to those ports.

If you add additional switches, including logical switches, to the fabric, bottleneck detection is not
automatically applied, so be sure to enable bottleneck detection on those switches as well.

NOTE

It is recommended that you enable bottleneck detection on every switch in the fabric.

When you enable bottleneck detection, you also determine whether alerts are to be sent when the
bottleneck conditions at a port exceed a specified threshold. The alert parameters include whether
alerts are sent and the threshold, time, and quiet time options. These alert parameters apply to all
ports in the switch, unless you override them later.

After you enable bottleneck detection, you can change the alert parameters on all eligible ports,
switches, and fabrics.

NOTE

The best practice is to enable alerts and use the default values:

Congestion

80%

Latency

10%

Window

300 seconds

Quiet Time

300 seconds

Time threshold

0.8

Severity threshold

50

If you change the Window value, you should use a setting that is 300 seconds or higher.

If you change the alert parameters for a port, you can later cancel these settings and inherit the
settings from the switch. Refer to

“Inheriting alert parameters from a switch”

on page 1492 for

instructions.

Use the following steps to enable bottleneck alerts and configure alert parameters.

1. Select Monitor > Performance > Bottlenecks.

The Bottlenecks dialog box displays, as shown in

Figure 641

on page 1491.