Viewing port distribution data details – Brocade Network Advisor SAN + IP User Manual v12.1.0 User Manual

Page 415

Advertising
background image

350

Brocade Network Advisor SAN + IP User Manual

53-1002949-01

User-defined performance monitors

8

Viewing port distribution data details

Each bar on the port distribution graph maps directly to one of the five percentage ranges defined
for the distribution monitor (refer to

“Distribution performance monitors”

on page 339).

1. Double-click a bar in the graph.

The Monitor_Title Data Details dialog box displays.

2. Review the data.

The port distribution data details include the following fields and components:

Port — The port affected by the selected measure.

TX/RX — Whether the port is transmitting (TX) or receiving (RX) data. This column is not
available for all measures.

Measure_Type — This column depends on which measure you select for the monitor.

Common

-

Port Utilization Percentage — The memory utilization percentage.

-

Traffic — The traffic in mbps.

-

CRC Errors — The number of CRC errors.

FC

-

Link Resets — The number of link resets.

-

Signal Losses — The number of signal failures.

-

Sync Losses — The number of synchronization failures.

-

Link Failures — The number of link failures.

-

Sequence Errors — The number of sequence errors.

-

Invalid Transmissions — The number of invalid transmissions.

-

C3 Discards — The number of class 3 frames discarded.

-

C3 Discards TX TO — The number of transmitted class 3 frames discarded due to
timeout.

-

C3 Discards RX TO — The number of received class 3 frames discarded due to
timeout.

-

C3 Discards Unreachable — The number of class 3 frames discarded due to
unreachable destination.

-

C3 Discards Other — The number of class 3 frames discarded due to other
reasons.

-

Encode Error Out — The number of encode errors outside of the frame.

-

SFP Power — The SFP power in dbm.

-

SFP Voltage — The SFP voltage in mV.

-

SFP Current — The SFP current in mA.

-

SFP Temperature — The SFP temperature in Celsius.

FCIP

-

Compression Ratio — The compression ratio for the FCIP tunnel.

-

Latency — The latency for the FCIP tunnel.

-

Dropped Packets — The number of dropped packets.

Advertising