Adding a trap recipient to one or more switches

The SNMP Trap Recipients dialog box allows you to register any recipient as a trap recipient on
selected products. You can register different recipients for different products.

NOTE

You can register and unregister other recipient servers on the Fabric OS switches on a per-switch
basis. For IP products, you can perform registration only at the switch level.

To add a trap recipient to one or more switches, complete the following steps.

1. Select Monitor > SNMP Setup > Product Trap Recipients.

The SNMP Trap Recipients dialog box, shown in

Figure 734

, displays.

FIGURE 734

SNMP Trap Recipients dialog box

2. Click Add from the Action list.

3. Enter the IP address of the SNMP trap receiver (the recipient server) in the Recipient IP

Address field. This is a mandatory field. IPv4 addresses are accepted, but a Domain Name
System (DNS) name is not accepted.

4. Enter the SNMP trap port of the recipient in the Recipient Port field. This is a mandatory field.

Valid numeric values range from 1 through 65535 and 162 is the default.