Configuring frame delay – Brocade Network Advisor SAN + IP User Manual v12.1.0 User Manual

Page 1441

Advertising
background image

1392

Brocade Network Advisor SAN + IP User Manual

53-1002949-01

802.1ag Connectivity Fault Management

37

10. Review the hop details:

-

The Hop Details table lists the connectivity status for each remote MEP and MIP.

-

The hop number.

-

The MAC address of the remote MEP/MIP.

-

Whether the MEP or MIP forwarded the message.

-

The ingress or egress MEP and MIP.

For a linktrace on a VLAN service, displays the associated port name in the format of
Slot_Number/Port_Number.

For a linktrace on a VLL or VPLS, displays the IPv4 address of the peer product.

-

The ingress or egress action, based on the MEP or MIP direction:

If direction is DOWN, displays Ingress OK.

If direction is UP, displays Egress OK.

-

Relay Action

If the linktrace message is forwarded, displays FDB.

If the linktrace message reaches the MEP or MIP, displays HIT.

11. Click Close on the 802.1ag CFM Linktrace dialog box.

12. Click Close on the Configure 802.1ag CFM dialog box.

Configuring frame delay

You can access 802.1ag CFM from the following features:

VPLS Manager (requires the IP - MPLS – VLL prvilege with read-write or read-only permission)

VLL Manager (requires the IP - MPLS – VPLS prvilege with read-write or read-only permission)

VLAN Manager (requires the VLAN Manager prvilege with read-write or read-only permission)

NOTE

802.1ag CFM Frame Delay is only supported on IronWare Ethernet Routers devices running
firmware release 5.4 or later.

NOTE

You cannot configure an 802.1ag CFM on a maintenance end point (MEP) configured with dual
tagged VLANs.

Use frame delay to identify fault locations by sending a query between maintenance end points
(MEP) along the service path of the domain.

To determine frame delay between two MEPs, complete the following steps.

1. Choose one of the following options:

From the VPLS Manager dialog box, Views tab, choose one of the following options:

Select a device from the VPLS Peer Status/VPLS Name/VCID list and click 802.1ag
CFM.

Select the Peer Topology tab and right-click a device in the topology and select
802.1ag CFM.