Allied Telesis AT-S63 User Manual
Page 125
AT-S63 Management Software Command Line User’s Guide
Section I: Basic Operations
125
To specify the time difference between UTC and local time, in the range -
12 to +12 hours:
clock timezone plus|minus
value
Mode
Configure Terminal
Description
This command is used to enable and disable DST, and to specify the time
difference between UTC and local time. There is no AlliedWare Plus
command for setting the polling interval of the STNP client.
Example
This command enables daylight savings time on the SNTP client:
awplus> enable
awplus# configure terminal
awplus(config)# clock summer-time
This command disables daylight savings time:
awplus> enable
awplus# configure terminal
awplus(config)# no clock summer-time
This command specifies a time difference of -2 hours between UTC and
local time:
awplus> enable
awplus# configure terminal
awplus(config)# clock timezone minus 2
This command specifies a time difference of +4 hours between UTC and
local time:
awplus> enable
awplus# configure terminal
awplus(config)# clock timezone plus 4