Allied Telesis AT-S63 User Manual

Page 125

Advertising
background image

AT-S63 Management Software Command Line User’s Guide

Section I: Basic Operations

125

To specify the time difference between UTC and local time, in the range -
12 to +12 hours:

clock timezone plus|minus

value

Mode

Configure Terminal

Description

This command is used to enable and disable DST, and to specify the time
difference between UTC and local time. There is no AlliedWare Plus
command for setting the polling interval of the STNP client.

Example

This command enables daylight savings time on the SNTP client:

awplus> enable
awplus# configure terminal
awplus(config)# clock summer-time

This command disables daylight savings time:

awplus> enable
awplus# configure terminal
awplus(config)# no clock summer-time

This command specifies a time difference of -2 hours between UTC and
local time:

awplus> enable
awplus# configure terminal
awplus(config)# clock timezone minus 2

This command specifies a time difference of +4 hours between UTC and
local time:

awplus> enable
awplus# configure terminal
awplus(config)# clock timezone plus 4

Advertising