Chapter 17: Event Log and Syslog Client Commands

332

Section II: Advanced Operations

An example of the information displayed by this command with the FULL
parameter is shown in Figure 53.

Figure 53. SHOW LOG OUTPUT Command with the FULL Parameter

For definitions of the parameters, refer to “SET LOG OUTPUT” on
page 322.

Examples

The following command lists all the output definitions:

show log output

The following command displays the details of output definition number 5:

show log output=5 full

AlliedWare Plus

Command

Syntax

show log config

Modes

User Exec mode and Privileged Exec mode

Description

This AlliedWare Plus command lists the current settings of the two event
logs and any syslog definitions, and is equivalent to the standard
command without the FULL parameter. An example of the information the
command displays is shown in Figure 52 on page 331. This command
cannot display detailed information about the syslog definitions because it
does not have an equivalent parameter for the FULL parameter in the
standard command.

Example

awplus# show log config

Output ID .................... 2
Output Type .................. Syslog
Status ....................... Enabled
Server IP Address ............ 149.88.88.88
Message Format ............... Extended
Facility Level ............... DEFAULT
Event Severity ............... E,W,I
Event Module ................. All

Advertising