Alliedware plus command – Allied Telesis AT-S63 User Manual
Page 672
Chapter 35: GARP VLAN Registration Protocol Commands
672
Section VI: Virtual LANs
Examples
This command sets the Join Timer to 0.1 second, Leave Timer to 0.35
seconds, and the Leave All Timer to 11 seconds:
set garp=gvrp timer jointime=10 leavetime=35
leavealltime=1100
The following command sets the timers to their default values:
set garp=gvrp timer default
AlliedWare Plus
Command
Syntax
To set the Join Timer:
gvrp timer join
value
To set the Leave Timer:
gvrp timer leave
value
To set the Leave All Timer:
gvrp timer leaveall
value
Mode
Configure mode
Description
These AlliedWare Plus commands are identical to the standard command.
Example
This command sets the Join Timer to 0.2 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# gvrp timer join 20
This command sets the Leave Timer to 0.8 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# gvrp timer leave 80
This command sets the Leave All timer to 10 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# gvrp timer leaveall 1000