Set switch consoletimer, Alliedware plus command – Allied Telesis AT-S63 User Manual

Page 84

Advertising
background image

Chapter 3: Basic Switch Commands

84

Section I: Basic Operations

SET SWITCH CONSOLETIMER

Syntax

set switch consoletimer=

value

Parameter

consoletimer

Specifies the console timer in minutes. The range is 1
to 60 minutes. The default is 10 minutes.

Description

This command sets the console timer, which is used by the management
software to end inactive management sessions. The AT-S63 Management
Software automatically ends a session if it does not detect any
management activity for the duration of the console timer. This security
feature can prevent unauthorized individuals from using your management
station should you step away from your system while configuring a switch.
To view the current console timer setting, refer to “SHOW SWITCH
MODULE” on page 96.

Example

The following command sets the console timer to 25 minutes:

set switch consoletimer=25

AlliedWare Plus

Command

Syntax

exec-timeout

value

Mode

Line Console mode

Description

This AlliedWare Plus command is equivalent to the standard command.

Example

This example sets the console timer to 15 minutes:

awplus> enable
awplus# configure terminal
awplus(config)# line console 0
awplus(config-line)# exec-timeout 15

Command

Available

AlliedWare Plus

Advertising