Examples

The following command changes the IP address for output definition
number 5 to 149.55.55.55:

set log output=5 server=149.55.55.55

The following command modifies output definition number 6 to only send
messages from the RADIUS module of all severity levels:

set log output=6 module=radius severity=all

The following command changes the facility level and message format for
output definition 4. The facility level is changed to LOCAL1 (numerical
code 17) and the format to normal so that the messages include only
severity, module, and description:

set log output=11 facility=local1 syslogformat=normal

The following command changes syslog server definition 11 to send only
spanning tree and IGMP snooping events with a severity level of error or
warning:

set log output=11 module=stp,igmpsnooping severity=e,w

AlliedWare Plus

Command

Syntax

To set the facility level of an output definition:

log monitor facility default|local1|local2|local3|local4|
local5|local6|local7]

output-id

To define the severity level of the messages of an output definition:

log monitor level E|W|I

output-id

Modes

User Exec mode and Privileged Exec mode

Description

This AlliedWare Plus command is used to set the facility levels and the
severity levels of the output definitions. The severity levels are I for
Informational, E for Error, and W for Warning, You cannot set any of the
other parameters in the standard command with the AlliedWare Plus
commands.

Examples

This command sets the facility level on output definition 4 to Local5: