Show switch port – Allied Telesis AT-S63 User Manual

Page 179

Advertising
background image

AT-S63 Management Software Command Line User’s Guide

Section I: Basic Operations

179

SHOW SWITCH PORT

Syntax

show switch port[=

port

]

Parameter

port

Specifies the port whose parameter settings you want

to view. You can display more than one port at a time.
To display all of the ports, do not include a port
number.

Description

This command displays a port’s current operating specifications, such as
speed and duplex mode. The command displays the following port
information. (For an example of the information displayed by this
command, see Figure 36 on page 183.)

Port Description - Displays the name of the port. The default name is
“Port_” followed by the port number. To configure a port’s name, refer
to “SET SWITCH PORT” on page 162.

Port Type - Displays the IEEE standard of a port. For example, the port
type for a twisted pair port on an AT-9424T/SP switch is 10/100/
1000Base-T.

Status - Displays whether the port is currently enabled or disabled.
When disabled, a port does not forward network traffic. The default is
enabled. To disable or enable a port, refer to “DISABLE SWITCH
PORT” on page 154, “ENABL
E SWITCH PORT” on page 158, or “SET
SWITCH PORT” on page 162.

Link State - Displays the current link state between the port and the
end node. If the port has established a link with an end node, link state
will be “Up.” If there is no link, link state will be “Down.”

Configured Speed/Duplex - Displays the current configured settings for
speed and duplex mode on the port. The setting of “Auto” indicates the
port has been set to Auto-Negotiation, the default setting. To adjust a
port’s speed and duplex mode, refer to “SET SWITCH PORT” on
page 162.

Configured MDI Crossover - Displays the current configured setting for
MDI/MDIX on the port. If the port is set to Auto-Negotiation, this field
displays N/A, because the MDI/MDIX setting is set automatically on
the port. A value only appears in this field if you disable Auto-
Negotiation on a twisted pair port and set MDI/MDIX manually. This
field does not apply to a fiber optic port. To adjust a port’s MDI/MDIX
setting, refer to “SET SWITCH PORT” on page 162.