<6. Maintenance>

6-14

IM 11B08A01-01E

Note

Cards are installed within the pressurized enclosure. They must be installed in the original
condition to ensure explosionproof functionality.

(4) Disconnect the cables to the card, if any.
(5) Loosen the two screws to remove the card stopper.
(6) Hold the handle of the card and pull it out from the rack.

Note

• Always install a new card in the place of the card being replaced.
• The name of the card is labeled on the upper section of the rack. Insert the card into the

correct slot.

• Never customize by replacing with different function cards etc.

(7) Install a new card in the place of the card being replaced.
(8) Mount the card stopper and tighten the two screws.
(9) Close the control unit door and the electronics section cover for the oven unit.
(10) Reconnect cables, if any.

<Replacement Parts>

Item No.

Board Name

Part Number (AS)

Note

Control Section

1 Control CPU Card

K9802AA

(1x Ethernet, SHDSL)

K9802AB

(2x Ethernet)

K9802AC

(1x Opt)

K9802AD

(2x Opt)

K9802AE

(1x Ethernet, SHDSL, TIIS)

K9802AF

(2x Ethernet, TIIS)

K9802AG

(1x Opt, TIIS)

K9802AK

(2x Opt, TIIS)

2 COM Card

K9802CA

(2 ports)

K9802CB

(1 port)

3 User Programming Card

K9802DA

4 AI Card

K9802EA

(Voltage)

K9802EB

(Current)

5 AO Card

K9802FA

(Channel isolated)

K9802FB

(System isolated)

6 DIO Card

K9802GA

(DC)

K9802GB

(AC)

7 DI Card

K9802HA

8 DO Card

K9802JA

(DC)

K9802JB

(AC)

9 Safety Board 3

K9802LA

(Type 3, X Purge)

K9802LB

(Type 3, Y Purge)

K9802LC

(Type 2, X Purge)

K9802LD

(Type 2, Y Purge)

K9802LE

(Type 1, X Purge)

K9802LF

(Type 1, Y Purge)

10 Status Board

K9802MA

11 CTRL EV Board

K9802NA

2nd Edition : May 11, 2012-00