<Appendix B Terminology>

App.B-1

IM 11B08A01-01E

Appendix B Terminology

Operation Terminology

Term

Description

Icon/abbr.

Status

Status can be changed for each GCM.

This operation can be made by operators with use level C

or higher.

The change is possible only in the Stop mode.

Process

Normal measurement, calibration and validation

Manual

Manual

operation

Measurement Status

of Process

It can be changed for each GCM. This operation can be

made by operators with user level B or higher.

Stream Sequence Continuously measures streams in order specifi ed in

Stream Sequence

Stream

Specifi cation

Repeats the measurement of the specifi ed stream for the

preset number of times (0: continuous, 1-999)

Calibration/

Validation

Performs calibration or validation of the specifi ed number

Operation Mode and

Command

Operation mode can be changed for each GCM or for all

GCMs at the same time.

Run

Mode in which measurement is running.

Starts the measurement in the Process mode. This

operation can be made by operators with user level B or

higher.

Starts to display chromatograms in the Manual mode.

(It does not detect peaks, calculate concentration, or save

chromatograms.)

Pause

Mode in which measurement pauses.

Operates until the pause time specifi ed in the GCM

method in the Process mode. This operation can be made

by operators with user level B or higher.

Stop

Mode in which measurement stops.

Operates in the Process mode for the main cycle specifi ed

in the GCM method. This operation can be made by

operators with user level B or higher.

Stops the Run mode immediately in the Manual status.

Command

Cancellation

Cancels the operation mode command that is in the

operation queue in the Process mode. This operation can

be made by operators with user level B or higher.

Forced Stop

Stops the current operation mode forcibly in the Process

mode. This operation can be made by operators with user

level C+ or higher.

GCM

Using multiple ovens and detectors, and simultaneously

operating multiple methods, the GC8000 can measure

each component under optimum conditions. This reduces

the analysis time and achieves a fl exible confi guration that

meets customers’ needs.

A GCM is one virtual GC. When multiple GCMs are set,

the GC8000 works as much as multiple actual GCs.

Up to two GCMs can be set in an isothermal oven.

Up to two for one isothermal oven

Up to four for two isothermal ovens

Up to six for three isothermal ovens

The following settings are carried out for each GCM:

atmospheric-pressure balancing valve number, stream

valve number, stream identifi cation output, distillation

point, and peak common settings. The operations of

stream valves are set in the GCM method settings.

2nd Edition : May 11, 2012-00

App.B