RISCO Group LightSYS 2 User Manual

Page 100

Advertising
background image

Installer Programming

Page 100

Quick Keys

Parameter

Default

Range

foyer), which would have to be violated after entry in order to disarm 
the system, as follows: 

 In AWAY (FULL ARM) mode behaves as an Entry Follower zone. 

(see 



ZZ



above

)

 

 In Stay (ARM) mode, the zone will be bypassed. 



ZZ

 

I + Instant (Interior + Instant) 

 

Usually intended for non‐exit/entry doors, window protection, shock 
detection and motion detectors. 

 In AWAY (FULL ARM) mode behaves as an intruder (instant) zone. 
 In STAY (ARM) mode, the zone is bypassed. 



ZZ

 

UO Trigger 

 

 

For a device or zone, which if violated at any time triggers a previously 
programmed utility output, and is capable of activating an external 
indicator, relay, appliance, and so on. 



ZZ

 

Day  

 

Arm

 

Usually assigned to an infrequently used door, such as an emergency 
door or a movable skylight. Used to alert the system user if a violation 
occurs during the unset period (fault by day; Intruder at night), as 
follows: 

 With the system armed (either AWAY or STAY), the zone acts as an 

intruder zone. A violation of this zone after the system is aremd or 
during the exit delay time period causes an immediate intrusion 
alarm. 

 With the system disarmed , a violation of this zone attempts to alert 

the user by causing the POWER/

 LEDs on all keypads to flash 

rapidly. This directs the user to view the systemʹs trouble 
indications. 

 Optionally, such a violation can be reported to the Central Station as 

a zone trouble. (Refer to Report Codes: Miscellaneous, page.228) 



ZZ

 

24 Hours 

 

 

Usually assigned to protect non‐movable glass, fixed skylights, and 
cabinets (possibly) for shock detection systems. 
A violation of such a zone causes an instant intrusion alarm, regardless 
of the systemʹs state 

Advertising