RISCO Group LightSYS 2 User Manual

Page 76

Advertising
background image

Installer Programming

Page 76

Quick Keys

Parameter

Default

Range

 

 

Buzzer  Bell 

 No

  

Yes/No

 

YES: If an alarm occurs when the system is armed in the stay arm mode, 
a buzzer sounds for the time defined under Buzzer At Stay (see page 73) 
before the external sirens operate. 
NO
: An alarm in the Stay Arm mode causes sirens to operate 
simultaneously. 

 

 

Audible Jamming 

 No

  

Yes/No

 

Relates to the Jamming Time parameter, described on page 71 
YES: Once the specified time is reached, the Main Panel activates any 
internal sounders and sends a Report Code to the MS
NO
: Same as above, except the internal sounders do not operate. 

 

 

Exit Beeps at Stay   

 No

  

Yes/No

 

Determines whether the system will sound beeps during exit time in stay 
arming. 
YES
: Exit beeps will sound
NO
: Exit beeps will not sound. 

 

 

Forced Keyswitch 
Arming

         

 

 Yes

  

Yes/No

 

YES: Keyswitch or Proximity Key arming is performed on any partition. 
Any violated (not READY) zone(s) in the partition will be bypassed 
automatically. The partition is then ʺforce armed,ʺ and all intact zones 
are capable of producing an alarm. 
NO: The partition cannot be armed until all violated (not ready) zones 
are secured. 

Advertising