Installer Programming

Page 87

Quick Keys

Parameter

Default

Range

 

 

Installer Reset 
Confirmation   

 

 

No

  

Yes/No

 

YES: An installer reset confirmation is required in order to reset the 
system after a confirmed alarm. The system cannot be armed until an 
installer reset confirmation is performed. The reset can be done by 
entering the Anti code or entering the installation mode or by 
performing an “Installer reset” from the keypad. 
NO
: Any means can be used to arm or disarm the system (keypad, 
remote phone operation etc.). 

 

 

Key Switch Lock  

No

  

Yes/No

 

YES: Only a latched key switch zone can arm or disarm the system. 

Note

When the system has more than one zone defined as latch key switch, 
the arm/disarm operation will occur only after all these zones are armed 
or disarmed. 
NO
: Any means can be used to arm or disarm the system (keypad, 
remote phone operation etc.). 

 

Entry Disarm 

No

  

Yes/No

 

Determines if the system’s disarming depends on the entry time. 
YES
: Only a remote control can disarm the system during the entry time. 

Note

The system cannot be disarmed with a remote control while the system is 
armed. 
NO
: The system can be disarmed during any time using any disarming 
device. 