Page 82

Quick Keys

Parameter

Default

Range

 

 

Error Speaker Time Out 

 No

 

Yes/No

 

This option determines the duration of the alarm that is generated via the 
internal sounders (speakers) when the exit door is programmed as “Final 
Exit”, and it is not closed once the exit time expires (an “EXIT ERROR”). 
YES
: The “EXIT ERROR” alarm in the internal speaker matches the alarm 
bell timeout setting. 
NO
: The “EXIT ERROR” alarm in the internal speaker sounds 
continuously until user reset. 

 

 

Tamper Report  

 No

 

Yes/No  

 

This option determines if a tamper signal will be reported to the MS 
while the system is disarmed. 
YES
: A tamper signal will always be reported. 
NO
: A tamper signal will not be reported to the MS during the unset 
period. 

Note:

A tamper restore report to the MS is always reported, regardless of the 
“TAMPER REP” definition 

 

 

AC Trouble Arm  

 Yes

 

Yes/No 

 

YES: The system can be armed with an AC trouble detected in the main 
panel, power supply module or the bus sounder. 
NO
: The system cannot be armed with an AC trouble. 

 

 

Strobe Arm  

 No

 

Yes/No 

 

This option allows the strobe (internal or external activated by a utility 
output ‐ Utility output >Follow Partition > Strobe Trigger) to confirm the 
final arming of the system. 
YES
: A ten second strobe indication will occur after the system is armed. 
NO
: There will be no strobe indication when the system is armed. 

 

 

Final Night 

 Yes

 

Yes/No 

 

This option determines the behavior of a final exit zone when the system 
is armed at Stay. 
YES
: There is no need to open and close the door if the door is closed, in 
order to arm the system in Stay.  The zone behaves like a regular 
“EXIT(OP)” zone type
NO
: There will be no change in the operation of a final exit zone in Stay 
arming. 