Installer Programming

Page 121



Testing

The following menu is used to perform tests on the system. Note that each test refers to the 
last time the device was activated. Tests can be performed on the following elements: 

Quick Keys

Parameter

Default

Range



 

Self Test 

 

This feature provides an automated self‐test for a selected group of 
localized intrusion sensors (for example, glass break detectors, sound 
discriminators and shock sensors) which respond to an artificial source 
of noise and/or vibration. 

Automated self‐testing is especially useful when sensors are placed in 
high security areas where failure cannot be tolerated. 

Up to 16 zones can be designated for self‐testing. 

A sound or vibration generator should be used that can be placed close 
enough to the sensors to trigger them when the noise source is 
activated. A Programmable Output acts as the source of switched power 
for the noise/vibration generator (refer to Sensors Test, page 127). This is 
set to conform to the testing schedule. The schedule defines the time 
and day for the first test, and sets the times for repeated tests over a 24‐
hour period. 

A message is sent to the Central Station if all the related sensors are 
triggered during the test (if a Report Code has been defined).With 
successful completion of the self‐test, an entry is also placed in the 
system’s Event Log. 

If one or more of the sensors fails to trip during the test period, a self‐
test failure message is generated and sent to the Central Station. A 
record of the failure is also entered in the Event Log. 



 

Soak Test 

 

The Soak Test feature is designed to allow false alarming for predefined 
detectors to be bypassed from the system, while any alarms generated are 
displayed to the user for reporting to the MS. This is especially useful if 
Police response withdrawal is being threatened and a particular zone is 
causing unidentified problems. 

Up to 8 zones can be placed on Soak Test. Any zone placed in the Soak 
Test list is bypassed from the system for 14 days and is automatically 
reinstated after that time if NO alarms have been generated by it. 