RISCO Group LightSYS 2 User Manual

Page 16

Advertising
background image

Introduction

Page 16

Scheduling

Through the use of the systemʹs built‐in clock, it is possible to automate system operations at 
the same time on selected days of the week or at a specific time within the subsequent 24‐
hour period or during vacation periods. 
The system operations include: 

Scheduling automatic arming and disarming (of one or more partitions). 

Scheduling automatic operation of utility outputs. 

Restricting users from disarming during predefined time periods 

Event Logging

The LightSYS2 has the capability of storing up to 500 significant events, including arming, 
disarming, bypassing, alarms, troubles, restorals, and resets. These events are logged in order 
according to date and time, and when applicable, according to zone, partition, area, user 
code, keypad, etc. When appropriate, such events can be displayed on an LCD keypad or 
uploaded to the MS via the Configuration Software. 

Advanced Installation Tools

Auto Installation: For quick and easy installation, the system performs automatic 
installation of the modules connected to the bus. The system searches for the 
modules by automatically verifying their connection and operation through the bus‐
scanning feature and prompts the user to approve each module connection. The auto 
installation feature is performed automatically after defaulting the system or can 
also be performed manually. 

Self Monitoring 
o

The bus test enables the system to verify the connection and the operation of the 
modules connected to the bus by indicating the efficiency of each one on a 0‐
100% scale. Each result is individually displayed on the LCD keypad (or via the 
Configuration Software). 

o

A watchdog feature, which periodically (every minute) and automatically 
performs a comprehensive self‐test and reports when operating faults are 
found. 

o

A maintenance mode which, when selected, performs an active self‐check on 
many of its components. 

o

One‐man walk testing capabilities, enabling an installer or technician to check 
the operation of each contact and detector which, when tripped, produce 
audible feedback and are visibly logged at the keypad from which the test was 
initiated. 

Advertising