Settings

This option allows setting the system in compliance with specific standardization, languages, 
customer of panel default:  

System: Settings

Quick Keys

Parameter

Default

Range



DIP 2  

Enable 

 Enable/Disable 

Used to determine whether the LightSYS2 default switch SW1‐2 is 
enabled or disabled. 
Enabled: When power to the main panel is switched off and then on and 
SW1‐2 is in ON position , the Installer, Sub‐Installer and Grand‐Master 
codes will return to the original, factory default values. In this case, after 
entering the Installer Programming section, the system automatically 
enters the Automatic Accessories arming setting process. 

Toggle the enable/disable option with 



Default Panel 

 

 

Restores programming options to factory defaults. 
The panel default option will be followed by questions regarding the 

defaults of the labels and erasing wireless devices. Use 

 to select 

your option. (See page 68)  



Erase Wireless 

 

Erase wireless devices without changing the system current 
programmed parameters. Select the WL device to be erased. (Note: This 
entry appears only if a wireless device is registered in the system.)

 

Standard 

 

Sets the panel programming options in compliance with the selected 
standard: 

EN standards, page 84 
PD6662:2010, page 86 
CP01, page 88