RISCO Group LightSYS 2 User Manual

Page 158

Advertising
background image

Installer Programming

Page 158

Quick Keys

Parameter

Default

Range



Accounts 

 

The number that recognizes the customer at the monitoring station. You 
can define an account number for each monitoring station. These account 
numbers are the 6‐digit numbers assigned by the central station 

Notes:

Notes for Account Number in contact ID Communication Format

The account number will always be reported as 4 digits, for 
example: A number defined as 000012 will be reported as 0012 

If more than 4 digits were defined, the system always sends the last 
4 digits of the account number, for example: Account number that 
was defined as 123456 will be sent as 3456. 

In Contact ID you can place digits and letters A–F. The A character 
is always sent as 0 for example: Account number that was defined 
as 00C2AB will be sent as C20B. 

Notes for Account Number in SIA Communication Format: 

Account number for SIA should be defined as a decimal number 
(Only digits 0..9) 

Account number can be reported as 1 to 6 digits. To send an 
account number with less than 6 digits use the “0” digit, for 
example: For account number 1234 enter 001234. In this case the 
system will not send the “0” digit to the monitoring station. 

In order to send the “0” digit in SIA format, located at the left side 
of the number, use the “A” digit instead of the “0” digit. For 
example, for account number 0407 enter 00A407, for a 6 digit 
account number such as 001207 enter AA1207. 



Communications Format   

Enables the system to contact the monitoring station in order to obtain 
details of the communication protocol used by the digital  for each 
account.  

Note:

See Appendix D: Library Voice Messages  

 Contact ID: The system allocates Report Codes supporting 

ADEMCO Contact (Point) ID 

 

 SIA: The system allocates Report Codes supporting the SIA 

(Security Industry Association) format 