Installer Programming

Page 99

Quick Keys

Parameter

Default

Range



ZZ

 

I+ Exit/Entry 1  (Interior+ Exit/Entry 1) 

Used for Exit/Entry doors, as follows: 

If the system is armed in the AWAY (ARM) mode, the zone(s) 

provide a delay (specified by Exit/Entry 1) allowing entry into and 
exit from an armed premises. 

 If the system is armed in the STAY mode, the zone is bypassed. 

Important:

For greater security when arming in the STAY mode, it is possible to 
eliminate the Entry Delay period associated with any zone(s), classified 

as Exit/Entry Delay 1 by pressing the 

 key twice, one after another. 

In effect, this makes it an INSTANT zone during the STAY mode of 
operation 



ZZ

 

I + Exit/Entry 2  
(Interior + Exit/Entry 2) 

 

Same as the I+Exit/Entry 1 parameter, described above, but the 
Exit/Entry 2 time period is applicable. 



ZZ

 

I + Exit(OP)/Entry 1 

Interior + Exit(OP)/Entry 1) 

 

Used for an exit/entry door that, for convenience, may be kept open 
when the system is being armed, as follows: 

 In AWAY (FULL ARM) mode behaves as an Exit (Op)/Entry 1 zone 

(see 



ZZ



above

).

 

 In STAY (ARMED) mode, the zone will be bypassed. 



ZZ

 

I + Exit(OP)/Entry 2 

Interior + Exit(OP)/Entry 2) 

 

Used for an exit/entry door that, for convenience, may be kept open 
when the system is being armed, as follows: 

 In AWAY (FULL ARM) mode behaves as an Exit (Op)/Entry 2 zone 

(see 



ZZ



above

).

 

 In STAY (ARMED) mode, the zone will be bypassed. 



ZZ

 

I+ Entry Follow  
(Interior + Entry Follower) 

 

Generally used for motion detectors and/or interior doors (for example, 