Installer Programming

Page 156

Quick Keys

Parameter

Default

Range



Voice 

 

Reports to the monitoring station will be done through the PSTN or GSM 
network. Reporting by Voice can be established through different 
channels. The optional channels depend on the hardware installed in 
your system. Select the required channel as follows: 

1. PSTN/GSM:  The system checks for the availability of the PSTN 

line. During regular operation mode all calls and data transmission 
are carried out using the PSTN line. In the case of trouble in the 
PSTN line, the line is routed to the GSM line. 

2. GSM/PSTN: The panel checks for the availability of the GSM line. 

During regular operation mode all calls and data transmission are 
carried out using the GSM line. In the case of trouble in the GSM 
line, the line is routed to the PSTN line. 

3. PSTN Only: The outgoing calls are executed through the PSTN 

audio channel only. Use this option for installations where no GSM 
line is available. 

4. GSM Only: The outgoing calls are executed through the GSM audio 

channel only. Use this option for installations where no PSTN line is 
available. 

Enter the monitoring station telephone number including area code and 
special letters (if required). If calling from PBX do not include the number 
for outgoing line. 

Function

Results

Stop dialing and wait for a new dial 
tone 

Wait a fixed period before continuing 

Send the DTMF * character 

Send the DTMF # character 

Delete numbers from the cursor 
position  

[*] 

 

simultaneously 

 



IP 

 

Encrypted events are sent to the monitoring station over the IP or GPRS 
network using TCP/IP protocol. 128 BIT AES encryption is used. RISCO 
Group’s IP/GSM Receiver Software located at the MS site receives the 
messages and translates them to standard protocols used by the 
monitoring station applications (For example; contact ID). 