Installer Programming

Page 86

Quick Keys

Parameter

Default

Range

 

 

20 Minutes Signal 

 No

  

Yes/No

 

YES: Prior to arming the system, the system will check for zones that did 
not send a signal for more than 20 minutes. These zones will be regarded 
as not ready. A partition assigned with a not ready zone cannot be 
armed. 
NO
: Prior to arming, the system will not check whether a zone did not 
send a signal for more than 20 minutes. 

 

Attenuation 

No

  

Yes/No

 

YES: The LightSYS2 device will be attenuated by six dB during the 
communication test. 
NO
: The LightSYS2 device works in normal operation mode. 

System: Controls: PD6662:2010

Quick Keys

Parameter

Default

Range



 

PD6662:2010 

 

 

 This section refers to controls that apply to DD243 approvals. 

 

 

Bypass Exit/Entry 

Yes

  

Yes/No

 

YES: It is possible for the user to bypass an Exit/Entry zone. 
NO
: An Exit/Entry zone cannot be bypassed. 

 

 

Entry Disable 

No 

 

Yes/No

 

YES: The alarm confirmation process will be disabled when the entry 
time starts. 
NO
: The alarm confirmation process will start when the entry time 
starts. 

 

Route Disable 

 No

  

Yes/No

 

YES: The panel disables the entry route zones (EX/EN, EX (OP)/EN, 
followers and Final Exit) from participating in the alarm confirmation 
process when the entry time starts. 

Note

Sequential confirmation can still be established from two confirmed 
zones, located off the entry route. 
NO
: The entry route zones will participate in the alarm confirmation 
process when the entry time starts. 