RISCO Group LightSYS 2 User Manual

Page 72

Advertising
background image

Installer Programming

Page 72

Quick Keys

Parameter

Default

Range



TX Supervise 

058 

1‐255 seconds 

Specifies how often a bi‐directional wireless device generates a 
supervision request to the system.  

If any of the accessories does not respond to the request, at least once, 
during the RX Supervision time, the system will regard the accessory as 
Lost.  

Notes

The device will generate the supervision message according to the 
time defined.  

Important: The RX Supervision time should be higher than the Tx 
Supervision time in order to eliminate false lost event. 



Service Mode 

020 

1‐255 seconds 

The time period that all tampers (main unit and accessories) can be opened 
for purposes of battery replacement without triggering a tamper alarm. 

 



AC Off Delay  

 30

  

 001‐255 minutes

 

In the case of a loss of AC power, this parameter specifies the delay period 
before reporting the event or operating the programmable output. If the 
delay time is set to zero, there will be no delay period. 



Guard Delay  

 30

  

 01‐99 minutes

 

Specifies the time period that the system will be unset after an authorized 
user enters a Guard code. 
 



Swinger Limit 

00 

 

 00‐15 times 

A swinger is a repeated violation of the same zone, often resulting in a 
nuisance alarm and usually due to a malfunction, an environmental 
problem, or the incorrect installation of a detector or sensor. 

This parameter specifies the number of

 

violations of the same zone

 reported 

during a single armed period, before the zone is automatically bypassed. 

Notes

Enter 00 to disable the swinger shutdown. 

EN 50131 compliance with swinger limit of no more than 10 times

 