Parameter

 

Exit/Entry Follow 

 

 

 

 

Activates the output when the selected partition(s) initiates an 
Exit/Entry delay period.

 

 

Fire Trouble Follow 

 

 

 

 

Activates the output when a FIRE TROUBLE is detected in the selected 
partition(s).

 

 

Day (Zone) Trouble 

 

 

 

 

Activates when a day zone trouble is detected in the selected 
partition(s).

 

 

General Trouble Follow 

 

 

Activates the output when a fault condition is detected in the selected 
partition.

 

 

Stay Follow 

 

 

 

 

Activates the utility output when the selected partition(s) is armed in 
STAY mode.

 

 

Tamper Follow 

 

 

  

A latched output activated when a tamper occurs in the selected 
partition(s) and follows any type of tamper. The output deactivates at 
tamper reset. 

 

Disarm Follow 

 

 

 

 

Activates the utility output when the selected partition(s) is disarmed.

 

 

Bell Follow 

 

 

  

This output enables the connection of different external sounders to 
different partitions. Activates the output when one of the defined 
partitions is in alarm mode and the bell is triggered. It will be activated 
for the programmed bell time or until the alarm is unset. 

Note:

The external sounder will not generate any squawk sounds 