RISCO Group LightSYS 2 User Manual

Page 132

Advertising
background image

Installer Programming

Page 132

Quick Keys

Parameter

 

Bell Stay Off 

 

 

 

 

This parameter causes the output to function as follows: 

In Away arming mode, the output will follow the bell activation 

in the defined partitions. 

In Stay mode, the output will not be activated. 

Notes:

If an alarm occurs in a zone that shares more than one partition and 
one of the partitions is in Arm mode (while the other is in Stay  
mode), the output will be activated, as described above. 

In Stay mode, a 24‐hour zone will not activate this output. 

 

 

Zone Bypass 

 

 

 

 

Activates the output when the relevant partitions are in Away or Stay 
mode and any zone in the relevant partitions is bypassed.

 

 

Automatic Arm Alarm 

 

 

Activates the utility output when there is a not ready zone at the end 
of the pre warning time during an auto‐arm process. The output 
restore shall be on Bell‐ Timeout or at user Disarm.

 

 

Zone Loss Alarm 

 

 

 

 

Activates the utility output when there is a lost wireless zone in the 
system. The output restore shall be on Bell‐Timeout or at user Disarm.

 

 

Bell Trigger 

 

 

 

 

Mainly used for the connection of different external sounders to 
different partitions in the UK. Activates the output when one of the 
defined partitions is in alarm mode and the bell is triggered. It will be 
activated for the programmed bell time out or until alarm is disarmed. 
This output generates squawk sounds and has a special sound for fire 
alarms. 

Note:

In fire alarm the output will not follow the bell delay time (see page 
70) but will trigger immediately. It will be triggered in pulsed 
sequence: five seconds on and two seconds off. 

 