Installer Programming

Page 71

Quick Keys

Parameter

Default

Range



Switch Aux Break 

 10 seconds

 

00‐90 seconds 

The time that the power supplied to the systemʹs smoke detectors through 
the programmable output is interrupted during a user‐initiated smoke 
detector reset, typically performed after a fire alarm or automatically 
when a fire verification is defined in the system control. (Refer to Double 
Verification of Fire Alarms, page 7777, for additional details.) 

Note

This feature is supported through any programmable output that is 
defined as Switch AUX . 



Wireless 

 

 

Specifies the time intervals relating to the operation of the wireless 
module 



Jamming Time  

None 

None, 10, 20 or  
30 seconds

 

Specifies the period of time that the LightSYSʹs wireless module tolerates 
unwanted radio frequencies capable of blocking (jamming) signals 
produced by the systemʹs transmitters. Once the specified time is reached, 
the main panel sends a report code to the alarm receiving center. (Refer to 
Jamming Fault, page 224.) 

NONE 

10 SEC  

 20 SEC 

 30 SEC  

NONE: No jamming will be detected or reported. 

Note:

Different sounds will be produced when jamming is detected, depending 
on the defined Audible Jamming time 



RX Supervise 

0‐7 Hours 

Specifies how often the system expects to get a signal from the systemʹs 
transmitters. If a signal from a zone is not received during the specified 
time the zone will be regarded as lost, the system will send a report code 
to the monitoring station, and the system status will be ʺNot Readyʺ. 

Note:

0

 hours disables supervision. 

It is recommended to set the supervision time to a minimum of 3 hours 