RISCO Group LightSYS 2 User Manual

Page 30

Advertising
background image

Mounting and Wiring

Page 30

Note:

To avoid bell loop trouble, if no connections are made to an internal siren, use a 2.2K 
resistor in its place. 

Wiring Bell Tamper

Connect the bell tamper to the BELL TMP and COM terminals on the main panel using 
2.2K resistor in serial.   

Important:

If you DO NOT use the terminal TMP BELL, remember to connect a 2.2K resistor 
(Resistor colors: Red, Red, Red) between TMP and COM.  
 

+ BELL: To connect to the self 
activated bell’s (SAB) positive hold 
off input. 

‐ LS: To connect to the SAB negative 
hold off input. 

BELL TMP: To connect to the bell 
input of the SAB Unit. 

Wiring Utility Outputs

The LightSYS utility outputs support a variety of power‐line device activation, 
whether resulting from: time dependency, external input, or device sensor. As detailed 
in Chapter 4, 3 Outputs, you can program customized device activation powerfully 
and granularly. 
For additional details, see page 43. 
 

 

To wire Utility

Output 1: 

Utility output 1 can be used to activate a self‐powered siren or any other self‐
powered device.  

Advertising