RISCO Group LightSYS 2 User Manual

Page 85

Advertising
background image

Installer Programming

Page 85

Quick Keys

Parameter

Default

Range

 

Restore Alarm 

 No

  

Yes/No

 

YES: The user must confirm that he is aware that alarm occurred in the 
system before rearming the system. The system/partition will be in “Not 
Ready” status until it confirms the alarm. The user needs to confirm the 
alarm by going to View > Alarm Memory  
NO
: The user does not need to confirm the alarm before rearming the 
system. 

 

 

Mandatory Event Log 

 No

  

Yes/No

 

YES: Only mandatory events (specified in the EN standard) will be 
displayed in the event log. 
NO
: All the events will be displayed in the event log. 

 

 

Restore Troubles 

No

  

Yes/No

 

YES: The user must manually confirm the restoral of each trouble to a 
normal condition. This is done from the User menu > View Trouble >
Press OK.
NO: The restoral report of each trouble is automatic . 

 

Exit Alarm 

Yes

  

Yes/No

 

YES: A violated zone outside the exit route will generate an alarm during 
the exit time. A report to the monitoring station for arming the system is 
sent at the beginning of the arming procedure. 
NO
: A violated zone outside the exit route will cancel the arming 
process. A report to the monitoring station is sent at the end of a 
successful arming procedure. 

 

 

Entry Delayed Alarm 

No

  

Yes/No

 

This feature is used to reduce false alarm reports to the MS. 
YES
: The report to the MS and the siren alarm will be delayed for 30 
seconds or until the end of the predefined entry delay (the shorter time 
of the two) following a violation of a zone outside the entry route. 
NO
: A violated zone outside the entry route will generate an alarm 
during the entry time and a report will be sent to the MS. 

Advertising