RISCO Group LightSYS 2 User Manual

Page 136

Advertising
background image

Installer Programming

Page 136

Utility Output: Pattern of Operation

Quick Keys

Parameter

Default

Range

 

Pulse N/C 

05 seconds 

 

01‐90 seconds

 

The utility output is always activated (N/C) before it is triggered 
(pulled down to negative). 
When triggered, it deactivates for the pulse duration specified below 
and then reactivates automatically. 

1.  Press 

 and then press 

 . 

2.  Choose the desired pulse duration, between 01‐90 seconds. 

3.

Press 

 and set the activation by choosing ALL or ANY using 

the 

 key.

 

4.

 Press 

 and define a label for the UO (refer to the note below).

 

 

Latch N/C 

 

 

The utility output is always Activated (N/C) before it is triggered 
(pulled down to negative). When triggered, it deactivates and remains 
deactivated (latched) until the operation is restored. 

1. Press and then press 

2. Using the 

 key select ALL or ANY to set the activation and 

press 

3. Using the 

 key select ALL or ANY to set the deactivation 

and press 

4. Define the output label and press 

  

 

Pulse N/O  

05 seconds

 

01‐90 seconds

 

The utility output is always deactivated (N/O) before it is triggered 
(pulled up). When triggered, it activates (is pulled down) for the 
pulse duration specified below, then deactivates automatically. 

1.  Press and then press 

2. Choose the desired pulse duration, between 01‐90 seconds 

3. Press 

 and set the activation by choosing ALL or ANY using 

the 

 key 

4. Select a label for the UO (refer to the note below). 