RISCO Group LightSYS 2 User Manual

Page 136

Advertising
background image

Installer Programming

Page 136

Utility Output: Pattern of Operation

Quick Keys

Parameter

Default

Range

 

Pulse N/C 

05 seconds 

 

01‐90 seconds

 

The utility output is always activated (N/C) before it is triggered 
(pulled down to negative). 
When triggered, it deactivates for the pulse duration specified below 
and then reactivates automatically. 

1.  Press 

 and then press 

 . 

2.  Choose the desired pulse duration, between 01‐90 seconds. 

3.

Press 

 and set the activation by choosing ALL or ANY using 

the 

 key.

 

4.

 Press 

 and define a label for the UO (refer to the note below).

 

 

Latch N/C 

 

 

The utility output is always Activated (N/C) before it is triggered 
(pulled down to negative). When triggered, it deactivates and remains 
deactivated (latched) until the operation is restored. 

1. Press and then press 

. 

2. Using the 

 key select ALL or ANY to set the activation and 

press 

. 

3. Using the 

 key select ALL or ANY to set the deactivation 

and press 

. 

4. Define the output label and press 

  

 

Pulse N/O  

05 seconds

 

01‐90 seconds

 

The utility output is always deactivated (N/O) before it is triggered 
(pulled up). When triggered, it activates (is pulled down) for the 
pulse duration specified below, then deactivates automatically. 

1.  Press and then press 

. 

2. Choose the desired pulse duration, between 01‐90 seconds 

3. Press 

 and set the activation by choosing ALL or ANY using 

the 

 key 

4. Select a label for the UO (refer to the note below). 