Installer Programming

Page 202

Quick Keys

Parameter

Default

Range



Type

    

 

 

Defines the way the external lamp will be operated. 

  ALWAYS ON–The lamp is always on. 

  ALWAYS OFF–The lamp is always off. 

  SCHEDULER– The lamp operates according to the time defined 

under the Sounder Lamp menu (Quick Key:



). 



Brightness

 

05

 

(01–10%)   

Used to set the brightness level of the external lamp. 



Power Source

 

SAB

 

SAB/SCB 

(Only for Lumin 8) 
Used to define the SAB or SCB power source mode of the LuMIN8.: 

  SAB—Power supply for the sounder will be drawn from the control 

panel. 

  SCB—Power supply for the sounder will be drawn from the 

sounder’s rechargeable battery. 



Siren Current

 

Standard 

Standard/Low 

(Only for Lumin 8) 
Set the sounder current mode. 

  LOW – The sounder output will be reduced to 106dB 150mA. 

  STANDARD  ‐ The sounder output will be 112dB 350mA (assuming 

single piezo head). 

 

Alarm Sound                                     

 

(Only for Lumin 8) 
Set the type of the alarm sound. Specify which of four alarm sounds is 
associated with this siren. 