RISCO Group LightSYS 2 User Manual

Page 50

Advertising
background image

Installing Bus Devices

Page 50


Jumper Description

BAT

Battery discharge protection

Protection
ON

If a continuous AC power outage occurs, the SMPS 
automatically disconnects the battery when its backup 
battery voltage drops below 10.8VDC. This is done to 
prevent ʺdeep discharge”

that may damage the battery

.

Protection
OFF

The battery may be totally discharged during continuous 
AC failure (no deep discharge protection).

Note:

If 2 pins configuration is selected, the battery might be damaged,
may  be required. 

Bell/LS

Used to determine the SMPS mode of operation in accordance with 
the sounder device connected to the BELL/LS terminals.  

Note:

The sounder(s) connected to the SMPS operates identically to the 
panel’s sounder(s).  

 

 

Bell

For a bell/electronic siren with a built‐in siren driver, 
position jumper on one pin; 12VDC is produced at the 
sounder’s terminals during burglary/panic alarms. Slow 
pulsing voltage is produced during fire alarm.

LS
(Speaker)

For a loudspeaker without a built‐in siren driver, position 
jumper on both pins. The SMPS produces continuous 
oscillating voltage for burglary/panic alarms and an 
interrupted oscillating voltage for fire alarm.

8. Locate the battery at the bottom of the SMPS box.  
9. Connect flying leads (battery connectors) from the SMPS board to the battery 

terminals ‐ (+) Red, (‐) Black). 

Note:

Use only lead acid battery type, rated 12V, 7‐21AH (maximum) and safety 
approved in accordance with the national standards! 

 

 