RISCO Group LightSYS 2 User Manual

Page 111

Advertising
background image

Installer Programming

Page 111

Quick Keys

Parameter

Default

Range

ZZ

Automatic Microwave Bypass   

No

 

Defines whether the MW channel will be bypassed or not while the 
detector identifies trouble in the MW channel. 
NO ‐ While detecting a problem in the MW channel it is not bypassed. 
Alarm condition cannot be established until the MW channel is fixed. 
YES ‐ Switches the detector to operate only in PIR mode in case of 
MW trouble 

ZZ

Green Line                   

Yes

 

A feature that follows environmental guidelines by avoiding surplus 
emission This feature defines the activation of the microwave channel 
while the system is disarmed. 
NO ‐ Green Line feature is disabled. MW is constantly activated. 
YES ‐ Green Line feature is activated. 

ZZ

Anti‐Mask                   

Enable

 

Defines the operation of Anti Masking detection. 
DISABLE ENABLE and behaves according to the settings defined in 
quick keys 

ZZ

 

ZZ

Arm/Disarm                

No

 

Defines the operation of the anti masking detection while the detector is 
armed or disarmed

.

NO – While armed or disarmed, anti‐mask behaves according to the 
setting defined in quick keys 



ZZ

above. 

YES – While armed, anti‐mask is disabled. When detector is disarmed 
Anti‐mask behaves according to the settings defined in quick keys 

ZZ

ZZ

Self Test                         

Remote

 

Used to test the detection technologies. In the event of a failed test, a Self 
Test Trouble is created 
REMOTE (Manual) ‐ The remote self test is performed by the system 
when a user manually selects the Diagnostics option from the 
Maintenance menu via the LightSYS2 User Functions menu 
LOCAL (automatic) ‐ Once an hour, the detector automatically checks 
that the detector’s channels are functioning properly. 