RISCO Group LightSYS 2 User Manual

Page 118

Advertising
background image

Installer Programming

Page 118

2-Way PIR, Shock, Flood, Gas, Curtain, High Temperature, Zone Button,
WatchOUT and Wired IR Beam

Quick Keys

Parameter

Default

Range

ZZ

Serial No.

 

The identifying 11‐digit number on the detector sticker 

ZZ

Control

 

 

ZZ

Supervision                          No                              Yes/No

 

Determines if this zone will be supervised by the system expander 
according to the time defined under the timer RX Supervision (see page 
71)..

 

ZZ

LED Enable                         Yes                               Yes/No

 

Defines whether or not the LEDS operation mode is enabled 

ZZ

Anti Mask (WatchOUT Only)    No                              Yes/No

 

Defines the operation of Anti Masking detection and behaves according 
to the settings defined in quick keys 

ZZ

 

ZZ

Detection Mode                   2.5 Min                         2.5 min/ 2.5 sec

 

 Normal 2.5 Min  Fast 2.5 Sec

If automatic detection mode is enabled, designate here the polling 
periodicity of alarm generating events. 

ZZ

Sensitivity

 

Defines the visual sensitivity of the detector. 
LOW  HIGH
LOW MEDIUM  HIGH MAXIMUM (WatchOUT only) 

(For IR Beam) Defines the sensitivity of the detector (how long must 
the beam transmission be interrupted to generate an alarm event) 
LOW  900 mSEC MEDIUM 675 mSEC  HIGH 450 mSEC 
MAXIMUM 225 mSEC