Page 102

Quick Keys

Parameter

Default

Range



ZZ

 

Latch Keyswitch

 

 

Connect an external SPST latched (non‐momentary) keyswitch to any 
zone terminals given this designation and operate the keyswitch, as 
follows: 

 After arming one or more partitions using the keyswitch and then 

disarming using the keypad, the related partitions will be disarmed. 
In order to arm the partition using the keyswitch again, turn the key 
to the disarm position and then to the arm position. 

 If a keyswitch latch is assigned to more than one partition and one of 

the partitions is armed by using the keypad (the keyswitch stays in 
the disarm position), then: 

When changing the position of the keyswitch to the arm 
position, all the disarmed partitions, which belong to this 
keyswitch, will be armed. 

When turning the keyswitch to the disarm position, all the 
partitions will be disarmed. 



ZZ

 

Entry Follower + Stay 

All

 

Assigned to motion detectors and to interior doors protecting the area 
between the entry door and the keypad, as follows:  

 In STAY (ARM) mode, a zone(s) given this designation behaves like 

an Exit/Entry zone and is subject to the Entry and Exit Delay time 
periods specified under Exit/Entry Delay 1. (Refer to Exit/Entry 
Delay 1, page 95.) 

 In AWAY (ARM) mode, a zone(s) given this designation behaves 

like an Entry Follower Zone and causes an immediate intrusion 
alarm when violated unless an Exit/Entry zone was violated first. 

 If so, an Entry Follower + Stay zone(s) remains bypassed until the 

end of the Entry Delay period. 



ZZ

 

Pulsed Keyswitch Delay

 

 

Used to apply the Exit/Entry Delay 1 parameter to the momentary 
keyswitch operation. (see 



ZZ



above) 



ZZ

 

Latch Keyswitch Delay

 

 

Used to apply the Exit/Entry Delay 1 parameter to the latched keyswitch 

operation. (see 



ZZ



above.) 