RISCO Group LightSYS 2 User Manual

Page 66

Advertising
background image

Installer Programming

Page 66

3. Enter the  bus detector ID number as set by the detectorʹs DIP switches (01‐32) 

Note:

The display ʺ(x:yy) Type: Noneʺ represent the bus detector location in the 
system. In the 0:yy designation, the 0 denotes that the bus detector is on the 
main unit and is not assigned to a bus zone expander. The yy represents the bus 
detector ID number (up to 32) as set by the detectorʹs DIP switches. 

4. Using the arrow keys move to the Type field. Use the 

 key to select the 

detectorʹs type. 

5. Repeat steps 2 ‐ 4 for other bus detectors. 

Step 2: Set Bus Zone Basic Attributes

1. From the main Installer menu select [1] Zones > [1] Parameters > [1] One by

One

 

2. Select the zone number that the bus zone was assigned to and press 

.  

3. Configure the parameters for the relevant bus detector. 

Step 3: Programming the Bus Detectors Advanced Parameters

1. From the main Installer menu select [2] Zones > [1] Parameters > [2] By

Category > [7] Advanced > [4] BZ Parameters

 

2. Select the zone number that the bus zone was assigned to and press 

.  

3. Configure the parameters for the relevant bus detector. 

Programming bus detectors on a bus expander

Using bus expanders you can create a separate bus loop that is used only for the bus 
detectors connected to it. The separate bus loop increases the total system security in 
case a certain bus detector is sabotaged. Up to four bus expanders can be added to 
the LightSYS (See diagram page 55) 

Step 1: Adding the Bus Expander to LightSYS2

Note:

If you already performed Auto Settings skip to Step 2 below: Assign Bus Detectors to 
a Zone ID and set basic parameters. 
1. From the main installer menu press 



 

 

 

 

to enter the Bus Expander 

menu. 

2. Using the arrow and numeric keys select a bus zone expander ID. 

3. Using the arrow keys move to TYPE. Use the 

 key to select a BZE32 and 

press 