RISCO Group LightSYS 2 User Manual

Page 189

Advertising
background image

Installer Programming

Page 189

Quick Keys

Parameter

Default

Range

2. Use the 

 or  

 keys to position the cursor over the ID 

filed and enter the Bus Zone ID number that you are assigning 
or deleting. Make sure that the detectorʹs physical ID number 
is identical to the ID number you select during programming. 

3. Using the arrow keys move to the Type field. Use the 

 

key to toggle and select the detectorʹs type: 

OPR12: WatchOUT PIR  

ODT15: WatchOUT DT  

WatIN: WatchIN 

ILun3: Industrial Lunar Grade 3  

iDTG3: iWISE DT Grade 3 

iQUG3: iWISE QUAD Grade 3 

iDTG2: iWISE DT Grade 3 

iQUG2: iWISE QUAD Grade 2 

BZ1: Single BUS zone expander 

4. Press 

 to confirm. Repeat the process for the other bus 

detectors 

Note:

The iWISE BUS detectors have additional input on board. When 
selecting iWISE Bus detector the following question will appear: ʺLink 
Bus Detector to zone xx? ʺ
 Selecting Yes will assign the input as the 
consecutive zone of the selected iWISE Bus detector.  
For example: If Bus detector with ID 0:01 (Zone 1 in the system) is 

defined as iQUG3 then the input of the zone

 

will be assigned as Zone

 2.  



 



 

GSM 

 

To specify and configure an installed GSM/GPRS module 

1. Through the menu selection, the following display appears: 

GSM MODULE

TYPE=NONE

2. With the cursor positioned at the TYPE field, use the 

 key 

to toggle and choose the GSM option. 

3. Press 

 to store your choice 