Follow Code

The code menu parameters enable you to program the activation of the selected 
utility output when the user chooses the user functions menu (Selects 

ACTIVITIES/UTIL OUTPUT, enters an authorized user code and presses 

. The 

installer designates the user code(s) for triggering the selected UO. 

Refer to the LightSYS2 User’s Manual for additional details about triggering utility 
output(s) via user codes. 

Note:

The utility output is activated by entering a user code only if the Quick UO 

parameter under System Control is defined as Disabled. When the Quick UO is 
defined as Enabled, no user code is required.  

To access the Code sub‐menus: 

1. Access the outputs menu, as described on page 125. 

2. From the Utility Output menu, press 

. The following display appears:  

UO=01 FOLLOWS:
4) CODE

3. Press 

 

to display the following

:

 

CODES FOR UO=01:
00)GRAND N

4. Use the 

 and 

  keys to select from any of the 16 available users codes. 

5. Use the 

 key to toggle between Y YES or N NO for each user chosen to trigger 

the designated utility output. 

6. Press 

 and proceed to Pattern of Operation, to set the pattern and duration of 

operation 