Installer Programming

Page 84

Quick Keys

Parameter

Default

Range

 

Configuration Software 
(U/D) Enable
 

 Yes

  

Yes/No 

 

YES: Enables communication between the alarm company and the 
LightSYS2 main panel using the configuration software. This enables 
modifying an installationʹs configuration, obtaining status information, 
and issuing main panel commands, all from a remote location. 
NO
: Disables communication, as detailed above. 

 

Cloud Enable 

 No

  

Yes/No 

 

YES: Enables communication between the LightSYS2 system and the 
RISCO Cloud.  
NO: Does not enable communication, as detailed above. 

System: Controls: EN 50131

Quick Keys

Parameter

Default

Range



 

EN 50131 

 

 

 This section refers to controls that apply to EN 50131 approvals.  

 

 

Authorize Installer 

 No

  

Yes/No

 

This option limits the installer and sub‐installer authorization to access 
the programming menu. 
YES
: A grand master code is required to authorize the installer to enter 
the programming mode for one hour. 
NO
: The installer does not need an authorization code. 

 

 

Override Trouble 

 Yes

  

Yes/No

 

Specifies if the system/partition can be armed when there is a trouble in 
the system. 
YES
: The system will arm even if there is a trouble in the system. 
NO
: When the user starts the arming process and there is a system‐
trouble, the user must confirm that he is aware of all troubles before 
continuing with the arming process. The user needs to scroll the list of 
troubles. At the end of the list the following question will appear: 

« Override Trouble? » Using the 

 key he needs to toggle the option 

to Y and press  

.

 