Quick Keys

Parameter

Default

Range

The number that recognizes the customer at the monitoring station. You 
can define an account number for each monitoring station. These 
account numbers are the 6‐digit numbers assigned by the monitoring 
station. 

Notes:

Account Number Communication Format: 

The account number will always be reported as 4 digits, for 
example: A number defined as 000012 will be reported as 0012 

The account range depends on which protocol is in effect, as 
follows: 
Protocol                        Range 
LARS                           0000–7779 (First 3 digits: 0–7 only) 
LARS1                         0000–1FFF 
LARS2                         0000–FFFF 
If more than 4 digits were defined, the system always sends the 
last 4 digits of the account number, for example: Account number 
that was defined as 123456 will be sent as 3456. 

 

System

 

LARS     0–3 
LARS1   0–7 
LARS2   0–F 

Use the one‐digit system code to efficiently allocate transmitter 
reporting among monitoring stations. 

 

Periodic Test

 

00 

HR:     00–96 
MIN   00–59 

The Periodic Test enables you to set how often the system will 
automatically establish communication to the monitoring station in 
order to confirm operational functionality. The periodic test involves 
sending the account number and a valid test report code (Contact ID 
602).  

 

No. Comm. Parameter

 

060 

0‐255 

Specify the timeout threshold for establishing communication between 
the LRT and bus, which upon being reached, triggers an event report to 
the monitoring station.