RISCO Group LightSYS 2 User Manual

Page 119

Advertising
background image

Installer Programming

Page 119

2-Way Magnet (X73)

Quick Keys

Parameter

Default

Range

ZZ

Serial No.                      

Normal

 

The identifying 11‐digit number on the detector sticker 

ZZ

Control

 

 

ZZ

Supervision                          No                              Yes/No

 

Determines if this zone will be supervised by the system expander 
according to the time defined under the timer RX Supervision (see page 
71)...  

ZZ

LED Enable                         Yes                               Yes/No

 

Defines whether or not the LEDS operation mode is enabled 

ZZ

(M&F Univ only)  

 

Magnet Enable     Yes                           Yes/No 

 

 

Yes (Enable) or  No (disable) the transmitter’s magnet. 

ZZ

Alarm Hold On                       On                           On/Off

 

Use this parameter to define the minimum period between alarm 
broadcasts.  

ON: Only one alarm message is transmitted in any 2.5 minute time‐
period 

OFF: Alarm detection is immediately transmitted 

ZZ

Input Termination            N/O                           N/O, N/C, DEOL 

Use this parameter to program the connection type used for each of the  

system’s zones. 
(F Shutter only) 

Shutter: Specifies that the Input 2 will count the 

number of open and close pulses received. If the zone exceeds the 
predefined number of pulses, the zone will be tripped and act according 
to its type definition. After a 25‐second timeout, the pulse counter is 
restarted. The pulse length is the currently defined Loop Response time 
period. 

 N/O: Uses normally‐open contacts and no terminating End‐of‐Line 
Resistor. 