System: Controls: CP-01

Quick Keys

Parameter

Default

Range



 

CP‐01 

 

 

This section refers to controls that apply to comply with SIA CP 01. 

 

 

Exit Restart   

 No

 

Yes/No

 

This parameter is used to define if an exit time shall restart one 
additional time while an entry/exit zone is tripped twice during exit 
time. 
YES
: Exit time will restart for one time only when an entry/exit zone is 
tripped during exit time. 
NO
: Exit time will not be affected if an entry/exit zone is tripped during 
exit time. 

 

 

Auto Stay 

 No

 

Yes/No

 

This parameter is used to define the system’s arming mode when using a 
keypad and no exit/entry zone is tripped during exit mode. 
YES
: If no exit/entry zone is tripped during exit time the system will be 
armed in STAY mode. 
NO
: If no exit/entry zone is tripped during exit time the system will be 
armed in Away mode. 

System: Controls: Device

Quick Keys

Parameter

Default

Range



 

Device 

 Yes 

Yes/No 

 This section refers to controls that apply BUS device 

 

 

Anti Mask = Tamper  

 No

  

Yes/No

 

Used to determine the operation of Anti Masking detection in a bus 
zone. 
YES
: Anti mask violation will activate tamper alarm. 
NO
: Anti mask violation will be regarded as trouble event. 