Installer Programming
Page 200
Quick Keys
Parameter
Default
Range
Strobe
Use this menu to define parameters relating to the sounder strobe
Control
Follow Bell
Defines the strobe operation mode.
ALWAYS OFF ‐ The strobe is deactivated.
FOLLOW BELL — The strobe is activated when the siren bell is
triggered.
FOLLOW ALARM — The strobe is activated when an alarm occurs in
the selected siren’s partitions.
Blink
40
Defines the number of times that the strobe will blink in a minute.
20 [Times/Min]
30 [Times/Min]
40 [Times/Min]
50 [Times/Min]
60 [Times/Min]
Arm Squawk
01 01‐20 (seconds)
The time that the strobe will blink when the system is armed.
Note:
If the siren’s squawk strobe is defined as NO (Refer to the add/delete
module,
page 187) this parameter will be ignored.