Mounting and Wiring

Page 29

Wiring Auxiliary Devices

Use the Auxiliary Power AUX (+) COM (‐) terminals to power PIRs, glass‐break detectors 
(4‐wire types), smoke detectors, audio switches, photoelectric systems and/or any device 
that requires a 12V DC power supply. 
 

Notes:

If the auxiliary outputs are overloaded (exceed 800mA) and are shut down, you must 
disconnect all loads from the outputs for a period of at least 10 seconds before you 
reconnect any load to the auxiliary outputs. 

LightSYS2 supports 4‐wire smoke detectors. To connect a 4‐wire smoke detector or 
device that requires resetting after an alarm condition, connect the auxiliary power 
AUX and output terminals. Use a power supervision relay to supervise the 4‐wire 
smoke detectors. Loss of power to the detector(s) de‐energizes the relay, causing a 
break in the zone wiring and a “Fire Fault” message at the panel. Remember to define 
the Output as Switched Auxiliary. 

In addition, when connecting a 4‐wire smoke detector, observe the wiring guidelines 
mentioned in the previous sections, along with any local requirements applicable to 
smoke detectors, as per the following diagram: 

 

To prevent a possible drop in voltage due to current requirements and distances 
involved, make sure to use the appropriate wire gauge (refer to the table of gauge sizes 
in) Appendix A Technical Specifications. 

To increase your power supply when employing multiple auxiliary devices, you can 
use the optional power supply expansion module (refer to the Wiring Power Supply 
Expansion Modules section, page 46) 

Wiring Internal Bell

The Bell/LS terminal provides power to the internal siren. When connecting an internal 
sounding device, pay attention to the polarity. 
It is important to position the BELL/LS DIP switch SW1 (see p. 37) correctly. The position 
varies depending on the type of internal siren.  
A maximum of 500mA may be drawn from this terminal.