Installer Programming

Page 116

Seismic

Quick Keys

Parameter

Default

Range

ZZ

Sensitivity                      

Normal

 

Defines the Seismic sensitivity of the detector. 
LOW MEDIUM NORMAL HIGH

ZZ

Interference (Accumula‐ 10 Sec                         10, 20, 40, 80 sec ‐ 
tion/Integration)  Time          

 

Defines the moving window of time in which the vibration signal is 
accumulated (integrated).  Detection is triggered when the accumulated 
signal reaches a threshold value.  Longer time causes higher detection 
sensitivity. 

ZZ

Explosion Sensitivity                     

Normal

 

Defines the explosion sensitivity of the detector. 
LOW MEDIUM NORMAL HIGH

ZZ

Temperature Sensitivity

 

Defines the sensitivity to temperature change. 
LOW HIGH

ZZ

Self Test                              

Remote

 

Used to test the detection technologies. In the event of a failed test, a Self 
Test Trouble is created 
REMOTE (Manual) ‐ The remote self test is performed by the system 
when a user manually selects the Diagnostics option from the 
Maintenance menu via the LightSYS2 User Functions menu 
LOCAL (automatic) ‐ Once an hour, the detector automatically checks 
that the detector’s channels are functioning properly. 

ZZ

LEDS                                   On

 

Defines the LEDS operation mode. 
OFF ‐ Disables the LEDS operation. 

ON

 – Enables the LEDS operation 