RISCO Group LightSYS 2 User Manual

Page 222

Advertising
background image

Wiring

Page 222

Max
External
Sounder
Current
(Max
current
draw per
branch)

Desired Wire Gauge in Particular Branch

32/02
mm

28/02
mm

24/02
mm

16/02 mm

Max Run

Max Run

Max Run

Max Run

Meter

s

Feet

Meter

s

Feet

Meter

s

Feet

Meters

Feet

100mA 

238 

780 

191 

625 

151 

495 

94 

310 

200mA 

229 

390 

95 

313 

76 

248 

47 

155 

300mA 

79 

260 

63 

208 

50 

165 

31 

103 

400mA 

59 

195 

48 

157 

38 

124 

24 

78 

500mA 

48 

156 

38 

125 

30 

99 

19 

62 

650mA 

37 

120 

29 

96 

23 

76 

15 

48 

Table A-5: Maximum External Sounder Current

Note:

The wire lengths indicated represent the one‐way distance between the LightSYS2 
and the external sounder in the branch. 