RISCO Group LightSYS 2 User Manual

Page 95

Advertising
background image

Installer Programming

Page 95

2 Zones

The LightSYS2 supports up to 32 zones. Each zone can be defined to be a wired zone, a 
wireless zones or a bus zone. The attributes for each zone vary according to the zone’s type 
(wired, wireless or type of bus zone). 
The Zones menu provides access to submenus and their related parameters that are used for 
programming the characteristics of each of the systemʹs protected zones. 
After you access the Zones menu from the main Installer Programming menu, as described 
in this section, you can access the following submenus: 



Zone Parameters, page 95 



Testing, page 121 



Cross Zones, page 122 



Alarm Confirm, page 124 



Parameters

The Parameters submenu allows you to program the zones parameters. You can program the 
basic parameters for a single zone (One by One) or a certain parameter for all zones at the 
same time (By Category) .  

Note:

In addition to the basic parameters described under this section, each zone has addition 
advanced parameters, quick key 2>1>2>7 



Zones: Parameters: One By One

Important:

When using the One by One method, the listing of each zoneʹs parameters is sequential. 
Once Zone 1ʹs parameters have been programmed, they are followed by Zone 2ʹs, then 
Zone 3ʹs, and so forth. 
To program one or more of the systemʹs zones using the One by One method, changes 
made to any (or all) of the Zone parameters will NOT be recorded without going through 
the entire Zone One by One list. 

The following procedure describes how to program the full complement of parameters for 
each zone on a one‐by‐one basis. 
The One by One menu contains parameters that enable you to program each of the following: 

 Zone Label, below  
 Zone Partitions, below 
 Zone Group, below 
 Zone Type, page 97 
 Zone Sound (Arm, Stay, Disarm), page 104 
 Zone Termination, page 105 
 Zone Loop Response, page 106 