Installer Programming

Page 113

Quick Keys

Parameter

Default

Range

ZZ

Arm/Disarm                  

No

 

Defines the operation of the anti masking detection while the detector is 
armed or disarmed. 
NO  – While armed or disarmed, anti‐mask behaves according to the 
setting defined in quick keys 

ZZ

above. 

YES – While armed, anti‐mask is disabled. When detector is disarmed 
Anti‐mask behaves according to the settings defined in quick keys 

ZZ

ZZ

Self Test                     

Remote

 

Used to test the detection technologies. In the event of a failed test, a Self 
Test Trouble is created 
REMOTE (Manual) ‐ The remote self test is performed by the system 
when a user manually selects the Diagnostics option from the 
Maintenance menu via the LightSYS2 User Functions menu 
LOCAL (automatic) ‐ Once an hour, the detector automatically checks 
that the detector’s channels are functioning properly. 

Bus Zone: ODT15 (WatchOUT DT)

Quick Keys

Parameter

Default

Range

ZZ

LEDS                              

3 LEDS

 

Defines the LEDS operation mode. 
OFF ‐ Disables the LEDS operation. 

RED ONLY

 ‐ Only the Red LED will operate. This option is highly 

recommended to avoid the possibility that a burglar will “Learn” the 
detector behavior. 
3 LEDS ‐ All 3 LEDs will operate. 

ZZ

PIR Sensitivity           

Normal

 

Defines the PIR sensitivity of the detector. 
LOW MEDIUM NORMAL HIGH

ZZ

MW (Microwave) Range   

Trimmer

 

Defines the microwave channel range. 
MINIMUM 20% 40% 60%  80%  MAXIMUM  TRIMMER  
(MW is defined by the trimmer setting on the PCB) 